GAE

Urut berdasarkan

GAE

GAE2

Last Updated: 1 April 2018
GAE CAP
CAPASITOR
MKP KVAR PHASE VOLT CODE PRICE
1.67 1 415 160101013      125,450
3.3 1 415 160101018      180,050
4.17 1 415 160101024      204,750
2.5 3 415 161202021      323,050
5 3 415 161202024      402,350
10 3 415 161202030      648,700
MKP-c Eco Series 15 3 415 168202612      793,000
20 3 415 168202618      942,500
25 3 415 168202624   1,098,500
30 3 415 168202630   1,248,000
40 3 415 168202636   1,690,000
50 3 415 168202642   2,067,000
MKPG 12.5 3 415 275.546 - 407700      759,850
15 3 415 275.556 - 409200      924,950
20 3 415 275.559 - 412300   1,095,250
25 3 415 275.278-415400   1,420,250
30 3 415 275.286 - 518500   1,722,500
40 3 415 160202030   2,047,500
50 3 415 160202636   2,730,000
MKPG type 480V 415 V 480 V CODE  PRICE
20 10.76 275.276 - 512300   1,202,500
25 13.45 160202624   1,524,900
MKPg type 525V 415 V 525 V CODE  PRICE
12.5 20 275.266 - 607700   1,398,150
25 40 160300618   2,376,400
MKP-c 525V 415 V 525 V CODE  PRICE
12.5 20 168300912   1,098,500
25 40 168300918   1,768,000
GAE REGULATOR
CAPACITOR  REGULATOR
ITEM TYPE CODE PRICE 
REGULATOR 6 STEP 3ACX06R-GAE-G Rp   2,799,920
REGULATOR 12 STEP 3ACX12R-GAE-G Rp   3,194,620
REGULATOR 14 STEP 3ACX14R-GAE-G Rp   3,830,255

TIMER THEBEN

Ttheben 181d 300e
TIMER THEBEN TYPE LIST
SUL181D  call 
HOUR COUNTER BZ 142-5                 Rp                                310,310
SKUN
SIZE STANDART HEAVY DUTY
2,5  -   Rp             1,931
4  Rp             2,685
6  Rp          2,653  Rp             3,783
10  Rp          4,350  Rp             4,706
16  Rp          8,550  Rp             7,930
25  Rp        10,180  Rp           11,765
35  Rp        16,140  Rp           15,665
50  Rp        24,170  Rp           23,855
70  Rp        33,300  Rp          38,740
95  Rp        47,560  Rp          47,060
120  -   Rp          55,250
150  Rp          65,163
185  Rp         124,150
240  Rp         147,225
300  Rp         233,188
400  Rp         347,425
500  Rp         844,350

METERING

AC Ammeter

am meter.jpg
Measuring Range Accuracy class Scale Design System Frequency Internal Consumption Frame Size Weight DIRECT CONNECTION : 0...10A, 0 ... 25A, 0...40A CONNECTION WITH CT: .../5A, .../1A 1.5 Overload scale I.e. upper scale value = 2x the measuring range Moving iron strip core system with oil dumping 50...100Hz 0.5VA 96x96mm and 72x72mm 210gr (96x96mm) and 150gr (72x72)
AC ammeter.jpg
AM Meter (with CT …/5A or 1A Special Order)
Scale (A) Frame Size
72x72 mm 96x96 mm
0 - 50, 60, 75, 100, 150, 200 Rp            417,825 Rp            345,600
0 - 250, 300, 400, 500, 600
0 - 800, 1000, 1200, 1500, 1600
0 - 2000, 2500, 3000, 4000, 5000
0 - 6000,
AM Meter (Direct Connection)
Scale (A) Frame Size
72x72 mm 96x96 mm
0 - 10, 25, 40  Rp          440,775 Rp            380,700

VOLT METER

volt-meter
Measuring range Acuracy class System Frequency/Internal Consumption Frame size/Weight DIRECT CONNECTION : 0...250V, 0...500V CONNECTION WITH PT : .../100V,.../110V Upper scale value = 1.2 x the measuring range for .../100V or .../110V Moving iron strip core system with oil dumping 50/60 Hz / 2.5 VA 96x96mm and 72x72mm / 220gr (96x96mm) and 160gr (72x72mm)
volt meter.jpg
Volt Meter
Scale (V) Frame Size
72x72 mm 96x96 mm
0 - 250, 500 Rp            467,100 Rp            394,200

DOUBLE VOLTMETER

double meter.jpg
Measuring range Scale design System Internal consumption Frame size/Weight 0…250 V~0…500V or for connection to …/100V or … /110V transformers Upper scale value = 1.2 x the measuring range for …/100V or …/110V Moving iron strip core system with oil dumping 2x 2.5VA 96x96mm/300gr
double-meter-spec
Double Volt Meter
Scale (V) Frame Size
96x96 mm
2 x 500V , 2 x 250V  Rp                                           931,500

ZERO VOLTMETER

zero meter.jpg
Measuring range System Internal consumption Frame size / Weight 0…800V, for 380~400V parallel operation Moving iron strip core system with oil dumping 4.5VA 96x96mm/210gr
zero voltmeter spec.jpg
Zero  Volt Meter
Scale (V) Frame Size
96x96 mm
0 - 800V Rp                                            870,750

FREQUENCY METER POINTER

frequency meter point.jpg
Measuring range Rated voltage Accuracy class System Internal consumption Frame size Weight 48…50…52Hz, 45...50...55Hz 100v, 110v or 220V 20% 1.5 Moving coil electronic frequency measurement 1.75W/22VA 96x96mm 230gr
frequency meter point spec.jpg
Frequency Meter (Pointer Type)
Measuring range  48 … 50… 52 Hz
Rated 100 V 110 V 220 V
Voltage Rp                                   1,113,750

FREQUENCY METER LED

frequency meter led.jpg
Measuring range Rated voltage Accuracy class System Number of LED Internal consumption Frame size Weight 48…50…52Hz, 45...50...55Hz 100v, 110v or 220V 20% 3 Electronic with LED display 9 0.58W/13VA 96x96mm 225gr
frequency meter led.png
Frequency Meter (LED Type)
Measuring range  48 … 50… 52 Hz
Rated 100 V 110 V 220 V
Voltage Rp                                   702,000

DOUBLE FREQUENCY METER

double frequency meter.jpg
Measuring Range Rated voltage Accuracy Class Display Burden Operating temperature Storage temperature Relative humidity Cable Size Weight 45…55Hz, 46…54Hz, 48…52Hz 380V+20%, 220V+20%, 110V+20%, 100V+ 20% 3 2x9 dots Bar Graph LED, Red 2x5VA/4W(max) 0°C…+50°C -10°C…+70°C 95% (non condensing) max 4mm2 403gr
double frequency meter spec.jpg
Double Frequency Meter (LED Type)
Measuring range  45 … 55 Hz
Rated 100-110V 220 V 380 V
Voltage Rp                    1,309,500

Cos ϕ Meter

cospi-meter
Measuring range Rated voltage/Rated current System Internal consumption Frame size/Weight 0.5cap. …1…0.5ind 100v,110v or 380V 20%/…/5A Moving coil zero crossing detection Voltage path = 1.73W/22VA, current path = 0.5W/0.5VA 96x96mm/260gr
cospi meter spec.jpg
Cos ϕ Meter
Weight 260 gr (96x96 mm)
Rated Volt 3 x 100 V 3 x 110 V 3 x 380 V
Rp                     2,409,750

ELECTROMECHANICAL kWh METER

kwh meter.JPG

Specifications

Rated voltage 3 X 220 V/380 V + 20%
Frequency 50Hz
Rated current 5A & 5(20)A
Connection 3 phase 4 wire
Accuracy Class 2
Display 6 Digits Mechanical Counter
Burden Voltage path : 5VA / 4W (max)
Current path : 3.44VA / 2.76W (max)
Operating temperature 0° C … +50° C
Storage temperature -10° C … +70° C
Relative humidity 95% (non condensing)
Meter Constant 200 rev/kWh
Weight 3307 gr
kwh meter spec.jpg
Electromechanical kWh Meter
Type Specification List
WH3-252 3P 4W, 5(20) A, 3x220/380V class 2         1,671,000
3P 4W, …/5 A, 3x220/380V class 2

Phase Failure Relay (PFR) GC1100

PFR GC1100 GAE.jpg

Specification

Nominal voltage Frequency Set point range Relay type Burden Operating temperature Storage temperature Relative humidity Weight Mounting 380Vac 50 Hz adjustable 5% … 25% of Nominal voltage SPDT – Contact rating 5A (cos? = 1), 250 Vac 5VA / 4W (max) 0° C … +50° C -10° C … +70° C 95% (non condensing) 324 gr DIN rail 35 x 7.5 mm
Phase Failure Relay (PFR)
Weight 400 gr (77.2 x 55 x 114 mm)
Price Rp                      769,500

WATER LEVEL CONTROLLER (WLC) GC2000

wlc gc2000.jpg

Specifications

Nominal voltage Frequency Distance between GC2200 and probes Relay type Burden Operating temperature Storage temperature Relative humidity Weight Mounting 220Vac + 20% 50 Hz ≤ 1000 m (with 2.5 sqmm control cable)SPDT – Contact rating 5A (cosφ = 1), 250 Vac 5VA / 4W (max) 0° C … +50° C -10° C … +70° C 95% (non condensing) 254 gr DIN rail 35 x 7.5 mm
Water Level Controller (WLC)
Weight 254 gr (77.2 x 55 x 70 mm)
Price Rp                562,275

LOAD BREAK SWITCH

LBS GAE.jpg

GENERAL CHARACTERISTICS

  • rated insulation voltage 1000V AC and 1500V DC
  • 3 poles available
  • high breaking capacity (AC-22, AC-23, IEC 60947-3)
  • high electrical and mechanical endurance
  • double break contacts
  • self cleaning contacts
  • contact position positively indicated by the handle
  • visibility of fixed and moving contacts by means of windows
  • independent manual operation
  • neutral contact makes earlier and opens later than the phase contacts
  • solid neutral version available
  • neutral at full current until 1250 A, standard, 1600 A ÷ 3150 A on request
  • suitable protection to prevent accidental touching of liveparts
  • casing in self-extinguishing (V0-UL94), low hygroscopic and high mechanical resistance isolating material
  • resistant to damp heat (IEC 6068-2)
  • wide range of accessories
  • rotary front operation by means of: external double insulated handle with door-interlock in ON position,
  • IP65 degree of protection. Padlockable with three padlocks in OFF position
  • direct handle (padlockable in OFF position on request).

RANGE COMPOSITION

LBS 3P - 4P.png

LOAD BREAK SWITCH 3P

LBS 3P.jpg

LOAD BREAK SWITCH 4p

lbs-4p

CHANGE-OVER SWITCHES

TWO LAYERS CHANGE-OVER SWITCHES

" Manual Change Over Switches 4P CMA Series "

COS GAE.jpg

GENERAL CHARACTERISTIC

  • 3 positions I-0-II
  • load break switches vertically or horizontally interlocked
  • visibility of fixed and moving contacts by means of windows
  • indipendent fast action operation
  • double break contacts
  • high breaking capacity (AC-23A IEC 60947-3)
  • high electrical and mechanical endurance
  • resistant to damp heat (IEC 68-2)
  • wide range of accessories
  • rotary front operation by means of:
o external double insulated handle with door interlock in I and II position. o IP65 degree of protection. Padlockable with up to three padlocks in 0 position.
  • version for by-pass available only up to 1250A 35kA
  • special executions of 6-8 poles changeover available.

RANGECOS SPEC 4P GAE.JPG

MOTORIZED CHANGE-OVER SWITCH

TWO LAYERS MOTORIZED CHANGE-OVER SWITCHES

" Motorized Change Over Switches 4P CMA Series "

MCOS-GAE.jpg
The range of motorized change-over switches is made by 14 sizes of switches of current rating from 160A to 3150A, 4 poles are available in the "CS" series with switch disconnectors laid one upon the other.
The CS series is made by 4 families:
MS, MSX, MSX1, MSY, differentiated between them mainly by the supply voltage and by the display of the position of the change-over switch. The horizontal CO series is made in the MS version only.

GENERAL CHARACTERISTICS

The motorized change-over switches are made by means of two switch disconnectors of "Visualcompact" series mechanically interlocked.
  • Automatic under-load change-over (AC22, AC23) from and to any of positions "1", "0", "2" both electrical and manual (emergency change-over), transfer function with direct transition from position "1" to position "2" and viceversa.
  • Front display of positions "1", "0", "2" by digital display and/or mechanical indicator (for MS version).
  • Safety: locking by padlock preventing any electrical or manual operation, key lock for the selection of electrical or manual operation (on MS series only).
  • External signalisation of positions "1", "0" and "2" by a clean contact (no voltage supply).
  • Easy and fast electrical connections by means of terminal blocks of quick connection type.

RANGEMCOS-GAE.jpg

detail